G-Type
This alternator has a specially wound stator to achieve high power output in a small, low weight package. High current diodes are used in the rectifier and internal fans provide forced air cooling. The output is controlled by a regulator inside the alternator. The units are assembled with stiff brush springs and extra flexible wire to connect the stator to the rectifier.
The stator is pegged to the body and all screws are locked. High quality bearings are used to enable the alternators to run at high speeds (up to 18,000rpm). The standard mounting method is intended for a belt drive, but the alternator may also be driven directly, if required.
Available as SMART G type alternators variants.
Documents
Electrical
- Output voltage 14.5V DC
- Nominal output current 180A at 10,000 RPM (cut in speed 3500rpm)
Communication interface
Optional CAN Communications Interface
- Voltage set point configuration
- On/Off control
- Diagnostic information, including:
- Regulator and rectifier temperatures
- Output voltage measurement
- Over-current warning
- RPM measurement
Mechanical
- Weight less than 3.5kg
- Aluminium alloy body
- Billet aluminium rear cover
- Maximum speed 18,000rpm
- Rotation clockwise or anti-clockwise
- Rectifier strapped
Design and manufacture is in-house, so if our existing designs do not suit your application, we can provide cost effective customised parts to suit even the most demanding application.
Please contact our technical consultancy service who will be pleased to help.
Connection Definition
- 22 AWG cable (where fitted)
- Positive power output M8 stud (B+ terminal)
- Ground connection for power and regulator is through the case. Ensures that the case has a high current, low resistance connection to vehicle ground
Cable connection
Green | Pin A | Pin 1 | Ignition |
Red | Pin B | Pin 2 | Sense |
White | Pin C | Pin 3 | Lamp |
Single connection details: Ignition and sense connections are through the power output stud (B+ terminal)
Environmental
- Splash resistant to standard motorsport fluids
- Continuous ambient operating temperature -30 to +90°C
- Maximum ambient temperature 110°C short term. Providing the following temperatures are not exceeded:
Stator | 200°C |
Diodes | 175°C |
Regulator | 105°C |
Bearings | 150°C |
Power Curve
Speed (RPM) | Voltage | Test Limit (Amps) |
5000 | 13.5 | 77 |
6000 | 13.5 | 112 |
7000 | 13.5 | 140 |
8000 | 13.5 | 156 |
9000 | 13.5 | 169 |
10000 | 13.5 | 180 |
11000 | 13.5 | 189 |
12000 | 13.5 | 197 |
13000 | 13.5 | 204 |
14000 | 13.5 | 212 |
15000 | 13.5 | 219 |
Motion Applied can service and repair alternators. Please contract our technical consultancy service for more information.
Ordercodes
- O 030 650 005 116
- 180 A Clockwise Rotation
- O 030 650 005 059
- 140 A Clockwise Rotation
- O 030 650 005 089
- 120 A Clockwise Rotation
- O 030 650 034 000
- 180 A Smart Alternator
- O 030 650 034 001
- 140 A Smart Alternator